SPECIFICATIONS
Input Rating |
Natural gas |
15,000 - 20,000 BTU/HR
4.4 - 5.8 KW/HR |
Propane |
16,000 - 20,000 BTU/HR
4.6 - 5.8 KW/HR |
Clearance to Combustibles |
VENT SIZE |
4" (102MM) FLEXIBLE
GAS LINER OR B VENT |
MANTLE CLEARANCE
FROM BOTTOM |
36" (915MM) |
SIDE CLEARANCE FROM
FACE PLATE |
PLEASE REFER TO
OWNER’S MANUAL |
Tested and approved to Canadian and American standards, ANSI Z21.88b-2003/CSA 2.33b-2003 and CAN/CGA-2.17-m91
|
|
|
Minimum Fireplace Dimensions |
OPENING HEIGHT
- MASONRY
- WOOD AND GAS ZC |
19.5" (495MM)
15.25" (387MM) |
DEPTH
- MASONRY
- ˜WOOD AND GAS ZC |
12" (305MM)
12" (305MM) |
REAR WIDTH
- MASONRY
- WOOD AND GAS ZC |
17" (432MM)
17" (432MM) |
OPENING WIDTH
- MASONRY
- WOOD AND GAS ZC |
25" (635MM)
25" (635MM) |
 |
Lifetime warranty on specific items.